Business, Commercial, Industrial Reverse Osmosis Systems

 

Industrial Water Softeners | Industrial Iron Filters | Industrial UV Systems| Irrigation | Request A Quote

Reverse Osmosis Selections: 400gpd - 1500gpd | 2000gpd - 12,000gpd | 15,000gpd - 25,000gpd | 30,000gpd - 500,000gpd

RainDance Water Systems Fully Integrated Compact Skid Mounted Reverse Osmosis Station

Fully Customizable To Fit Your Water Requirements - Skid Mount Water Filtration System

Need A Brochure? Request A Skid Mount Brochure & Price Guide

Email: Support@RainDanceWaterSystems.com Attn: Commercial Skid RO

reverse osmosis skid

 

The ultimate plug-and-play skid mount reverse osmosis setup, Commercial skid mounted ro systems are a robust solution for any customer's business water purification needs. All components are installed, plumbed and wired on a welded stainless steel frame. Simply place the skid where you need it, plugged in and provide with a water supply to start making pure water for any commercial water treatment need. Consult with our engineers to determine specific filtration needs.

 

 

 

WE INVITE COMPARISONS TO ANYTHING ON THE MARKET!

A must for brackish water, high minerals, sodium, sulfate, total dissolved solids (TDS), or where premium water purification is required. Unlike most multi-piece water treatment systems that are scattered throughout your business our commercial reverse osmosis mobile skid mount unit contains well water or city water pretreatment for iron, manganese, hydrogen sulfide gas, hard water, sediment, sand, silica and chlorine pretreatment, reverse osmosis, pump, re-pressure system, and UV Sterilization on a single skid mount base frame with wheels for easy positioning. And most important our Skid Series reverse osmosis systems are user friendly.

Create the ultimate water supply for your business with our user friendly Complete Skid Mount Series commercial reverse osmosis system. Each Skid Mount RO Series  includes: Complete city or well water pre-treatment for the removal of iron, manganese, hydrogen sulfide gas, suspended solids, chlorine and hard water. This state of the art integrated skid mount reverse osmosis system also includes ultraviolet UV disinfection to inhibit bio fouling of the RO membrane. See our premium standard features listed below. All components - (excluding storage tank) are contained on our skid mount platform with wheels - for easy positioning and mobility. Our Skid Mount Commercial Reverse Osmosis Systems are among the most water efficient systems in the industry. With the use of concentrate water recirculation our systems can achieve a recovery of 60% to 75% depending on feed water chemistry

How It Works: User Friendly! Everything within the skid is pre-plumbed and wired. There is a single point power inlet connection and the customer has to simply connect to the storage tank and then to his usage. Once our Integrated Skid Mount RO is installed and feed water is made available to it, the Storage Tank will begin to fill with product water. The product water will continue to fill the Storage Tank until the tank float switch closes and shuts the entire system off. At the same time, while the tank is filling, concentrate water will begin to flow into the connected drain system. The concentrate water will continue to flow to the drain system until the tank float switch closes and shuts the entire system off. When there is a demand for water, the Repressurization System is activated and draws product water from the Storage Tank. The product (RO) water is then delivered with the on skid re-pressure system to your application. If enough product water is used to the point where the float switch is reopened, the Skid Mount RO System is automatically reactivated and begins to replace the product water that has been depleted.

Why a RainDance Water Systems Top Of The Line Fully Integrated Skid Mount Reverse Osmosis System?

Our complete skid mounted reverse osmosis systems are designed for the customer who wants a state of the art, user friendly, multi-filtration system to filter and purify water for his/hers business needs. Reverse Osmosis is the same process that major water, beverage bottling, and pharmaceutical companies use. These systems are designed to filter brackish water, high levels of sodium and total dissolved solids (TDS), iron, manganese, treat hard water and more. If your well has salt water intrusion problems and high TDS, reverse osmosis is the solution.

RainDance Water Systems Pre-Plumb & Wired

 Integrated TV-RO Skid Series Standard Features

Fully Customizable For Both City & Well Water Sources

All components (excluding storage tank) located and contained on our skid mount platform with wheels - for easy positioning.

  • Approx. Weight & Skid Dimensions: 51"W x 32"H x 63"H / Estimated Dry Weight 500lbs (2,000gpd -4,000gpd)
  • Approx. Weight & Skid Dimensions: 58"W x 37"H x 63"H / Estimated Dry Weight 750lbs (6,000gpd -12,000gpd)
  • Includes on skid Single point power connection for 220V, 60 Hz, 1-Phase power. <Custom and Overseas power connections available>
  • Includes on skid (NO-Salt Discharge) Hard Water Treatment antiscalant feed system - Pretreats and protects the membrane from hard water scale, silica and highly mineralized water. Antiscalant hard water pretreatment method is preferable to salt based water softeners as it has more mineral pretreatment capabilities, no drain line waste water, lower maintenance, no salt pellets required, no salt discharge, economical, and is perfect for areas of the country that have chloride discharge limits. The antiscalant formulation has been certified by the National Sanitation Foundation (NSF) under ANSI/NSF Standard 60 for use in producing potable water.
  • Includes on skid digital automatic *"No-Maintenance" well water iron, manganese, hydrogen sulfide gas, and suspended solids pretreatment system or substitute our *"No-Maintenance" chlorine removal system for city water sources. *No maintenance refers to automatic backwashing capabilities and no routine media replacement required - media can last 5-10 years.
  • Includes on skid Pretreatment lock-out switch and manual bypass included for automatic backwashing systems.
  • Includes on skid Automatic Flush on start up - Fast clean-flushes membrane with pure water each time the unit starts.
  • Includes on skid microprocessor based controller - Controller includes digital product water conductivity indicator, Controller monitors feed water pressure, pump output pressure, product water conductivity, product water storage tank level and performs membrane flush on startup. Low feed pressure, high pump pressure and high product water conductivity result in alarm state indications. System control panel includes prefilter in and out pressure gauges, pressure vessel in and out pressure gauges, product water flow meter, recirc. flow meter with control valve and concentrate flow meter with control valve."Perfect for serviceman or do it yourselfer."
  • Includes on skid "Low Energy" High Rejection Membranes in Stainless Steel Pressure Vessel(s)
  • Includes additional testing monitor - Portable waterproof tester offers high accuracy electrical conductivity (EC), total dissolved solids (TDS) and temperature measurements in a single tester. Allows you to test untreated and post treated water.
  • Includes (2) - 35" dia. x 81" ht. 300 gallon storage tank. For ease of handling and ability to get through standard entry doorways we use a multiple array of tanks. Product water storage tank is green, with 16" manway, 2" bottom inlet/outlet (bushed to 1.25"). Two ea. .
  • Includes on skid 10gpm @ 48psi fully automatic electric pump (constant pressure) re-pressure system - Draws water out of the storage tank. Pump has integral switch for 40/60 psi output control and integral low feed water protection shutdown.
  • Includes on skid chemical free ultraviolet UV disinfection system. UV Sterilizer for disinfection of feed water to inhibit bio fouling of R.O. membranes.
  • Each skid mount reverse osmosis is fully assembled and tested before it leaves the plant.
  • For optimum Skid RO Series performance customers must have at least 7gpm @ 30psi available. Note: Our Skid RO Series contains complete pretreatment for chlorine and hard water (calcium) typically associated with municipal water sources. If Skid RO is to be used on well water we offer the following guidelines: Operating Parameters: Max TDS-5000ppm, Total iron is less than 10ppm, Manganese is less than 3ppm, H2S less than 10ppm, Water hardness below 250gpg, pH 6.5 -8.5, No iron bacteria. Calculations of production capabilities are based on a feed water temperature of 60 Deg. F. Lower temperatures may result in slightly lower production levels.
  • Unlike most companies , we are able to tailor our Skid RO systems to your needs. To ensure the longest trouble free system life and best possible treated water quality, we encourage you to fax (760-896-6999) or E-mail your water chemistry report or let us know the name of your municipal water district provider. You may also send us a water sample for evaluation.
  • FREE WOOD CRATING FOR SKID TO ASSURE SAFE DELIVERY.
  • FREE SHIPPING ON ALL RO SKID REVERSE OSMOSIS WITHIN THE CONTINENTAL UNITED STATES.
  • OVERSEAS SHIPPING AVAILABLE OR HAVE YOUR FREIGHT FORWARDER PICK-UP

RDWS-TV-RO-Skid Reverse Osmosis Systems Selection & Pricing

Skid RO Units Can Also Be Quoted Without Storage Tank & Re-pressure Pump

skid mounted ro system

Need A Brochure? Request A Skid Mount Brochure & Price Guide

Email: Support@RainDanceWaterSystems.com Attn: Commercial Skid RO

 

 

Model #

 

Description

 

Price

RDWS-TV-RO-SKID-2000

 Complete skid-mounted 2,000gpd reverse osmosis system includes all listed standard features and (2) 35"D x 80"H 300 gallon storage tanks.

 

 

RDWS-TV-RO-SKID-4000

Complete skid-mounted 4,000gpd reverse osmosis system includes all listed standard features and (2) 35"D x 80"H 300 gallon storage tanks.

  

RDWS-TV-RO-SKID-6000

Complete skid-mounted 6,000gpd reverse osmosis system includes all listed standard features and (2) 35"D x 80"H 300 gallon storage tanks.

   

RDWS-TV-RO-SKID-8000

Complete skid-mounted 8,000gpd reverse osmosis system includes all listed standard features and (2) 35"D x 80"H 300 gallon storage tanks.

 

RDWS-TV-RO-SKID-10,000

Complete skid-mounted 10,000gpd reverse osmosis system includes all listed standard features and (2) 35"D x 80"H 300 gallon storage tanks.

 

RDWS-TV-RO-SKID-12,000

Complete skid-mounted 12,000gpd reverse osmosis system includes all listed standard features and (2) 35"D x 80"H 300 gallon storage tanks.

 

 


Create the ultimate water supply with our user-friendly RDWS-TV-RO-SKID series with customized maintenance-free pretreatment for iron, manganese, hydrogen sulfide gas, suspended solids, and chlorine/chloramine, salt-free hard water pretreatment, UV disinfection pretreatment, and fully automated reverse osmosis membrane purification. All components (excluding storage tanks) are contained on our innovative skid mount frame with wheels for easy mobility and set-up. Our Skid Mounted Water Purification Series is among the most water efficient systems in the industry today, featuring low waste high recovery options up to 50%, 60%, even 70% on many water applications!

The RDWS-TV-RO-SKID series is designed for the customer who wants a state-of-the-art, user-friendly, multifiltration system to provide great water or top-quality product water for a multitude of commercial applications. These systems are pre-plumbed, pre-wired, and include (1) inlet feed water connection, (1) drain connection, (1) product water connection into storage tank, (1) delivery pump outlet connection, and (1) electrical connection to allow for fast, hassle-free installation. From the delivery of the equipment to your facility to using clean, purified water lies only hours, not days!

Need A Brochure? Request A Skid Mount Brochure & Price Guide

Email: Support@RainDanceWaterSystems.com Attn: Commercial Skid RO



Go Back to the Complete Commercial Reverse Osmosis Catalog Page >>>>

  • *Capacity production rate is based on input water temperature of 25 C (77 F). If your water is colder production will be lower.